|
MIP (Membrane Interface Probe)

“Finding Contaminant Mass To Optimize Remediation”



Vironex has provided direct push services across the U.S. since 1993 and operated our MIP Division since 2000. With the extensive resources and wide array of DPT platforms, Vironex has the capability of deploying the MIP with the deep application Geoprobe 6600, 6620DT, & 540M (Limited Access) rigs. Vironex’s MIP Division provides ECD, PID, and FID data with Soil Conductivity to identify petroleum and chlorinated hydrocarbon source zone contaminant distribution in both the saturated and unsaturated zone, and the extent of downgradient contamination.
Vironex’s unique MIP configuration and services enables the consultant to obtain relative contaminant concentrations, as well as being able to speciate contaminants through a continuous trapping system, and traditional confirmation soil, groundwater , and soil gas sampling.


Vironex assists environmental consultants nationwide in obtaining high definition site characterization data through our MIP System to allow them to obtain a better understanding of contaminant distribution in relation to lithology. This is critical information required to implement successful in-situ remedial programs.
Vironex also has the capability to cost effectively provide 3D imaging of contaminant mass distribution in relation to lithology as well as site landmarks. This capability allows consultants and their clients to gain a better visual perspective of the contaminant distribution.
Field data, images and reports can be transmitted real time from the field directly to the consultant’s desktop, as well as uploaded daily to a secure website where they can be accessed by project stakeholders through the internet.

ACTIVE STANDARD: ASTM D7352-07 Standard Practice for DPT for Volatile
Contaminant Logging with the MIP
Methodology For Integration of The MIP With In-Situ Remediation Injection Design
Triad
MIP Webinar – Spring 2005
Sensor Technologies Used During Site Remediation Activities –Selected Experiences
A Permeable Membrane Sensor For Detection of Volatile Compounds in Soil
Targeted Data Collection

Vironex MIP Value Proposition

Integration of site information into an MIP approach
Proven MIP performance
Customer references and case studies
Turnkey Services – DPT and Analytical
Will back performance with lump sum bids
Data evaluation and detailed reporting

 |
| |
| 3D Reporting PID Response vs. Lithology Underlying Site Map |

Benefits Over Traditional Sampling

Real time data allows site characterization location decisions to be made without waiting for soil or groundwater sample analysis.
Better vertical delineation: 20 samples per foot vs 1 sample every 5 feet for soil or one sample per monitoring well.
Measures total contaminant mass versus just soil, soil vapor, or groundwater.
Locates contaminant mass interface at unique lithologic zones.
Lower halogen detection limits than hand held PID.
PID and FID co-detection for petroleum hydrocarbons.
Digital output allows for easy mapping of mass vs lithology.
No fugitive emission losses.
MIP Direct Push Technology Platforms

Static and percussion advancement with Geoprobe 6600, 6620DT, & 540M (limited access) rigs. Vironex provides a turnkey MIP service deployment through our own equipment and employees. We do not subcontract any services.
Special Capabilities

Continuous trapping and speciation system, traditional confirmation soil, groundwater, and soil gas sampling, 3-D imaging, detailed reporting, integration of MIP data into in-situ remediation injection strategies.
Custom designed MIP Sprinter vans (2005) with pre-strung dual rod strings to minimize down time from broken probes or saturated trunk lines, the ability to implement the MIP through dual wall casing to prevent cross contamination, integrated low-noise generator, refrigerators for storage of confirmation samples, internet access, air conditioned, high end laptop / printer capable of generating 3-D imaging in the field.

 |
| |
| Interior of MIP Sprinter van showing detectors, MIP operating instrumentation, sample refrigerator, and temperature controlled consultant work area. |
 |
| |
| MIP Work Space For Client Interface and Real-Time Data Review |
 |
| |
| Mapping DNAPL Distribution In Relation To Top of Bedrock |
 |
| |
| Back-end of MIP Sprinter van showing pre-strung dual rod system, propane low noise generator, and detector gases. |
 |
| |
| Secure MIP data hosting with daily updates for project stakeholders who are implementing dynamic site characterization plans (e.g., Triad) |
Webinars

|
|